Detailaufnahme einer Rohrleitungsarmatur im Primärsystem eines Kernkraftwerks während einer chemischen Dekontamination.

Primary Circuit Decontamination

Chemically decontaminate primary and auxiliary systems of nuclear facilities.

Purpose and Application

Effective and comprehensive reduction of the dose rate in the nuclear power plant

For the chemical decontamination of PWR and BWR primary systems and the auxiliary systems in the nuclear power plant, SIEMPELKAMP NIS developed the ASDOC_D-MOD Process. This chemical decontamination process is operated and controlled by the plant equipment on site.

Learn more

The chemical decontamination process ASDOC_D-MOD

ASDOC_D-MOD uses well-known and freely accessible process chemicals in significantly reduced concentrations and with modified operating logistics. The chemical concentrates are injected into the reactor primary circuit via the site's dosing system and then circulated in the primary circuit.

Like in regular plant operation, the control of plant systems needed for the decontamination is performed by the operating personnel from the control room. Required parameters for e.g. dosing processes, throughputs or temperatures are given by SIEMPELKAMP NIS. Dissolved ions and nuclides from the primary circuit’s oxide layers are removed by means of the site’s ion exchange water clean-up system. The ASDOC_D-MOD process may be interrupted and restarted at any time without any precipitations of chemical compounds.

The decontamination process which is subdivided in several processing steps can precisely be terminated at the interface between oxide layer and base material. An unintentional damage of the base metal and hence and increase of waste can thus be prevented safely.